How to calculate the f2 similarity factor (with a worked example)

The similarity factor f2 compares two dissolution profiles — usually a test and a reference product — on a single 0–100 scale. Values of 50 or more are conventionally read as "similar". Below: the formula, the conditions that must hold before f2 is meaningful, and a complete calculation you can reproduce.

Open the f2 calculator Compare full profiles with bootstrap

The formula

f2 = 50 · log10 { [ 1 + (1/n) · Σ (Rt − Tt)² ]^(−0.5) · 100 }

Rt and Tt are the mean percentages dissolved for the reference and test product at time point t, and n is the number of time points used. Identical profiles give f2 = 100; an average difference of 10 percentage points at every time point gives f2 ≈ 50. The companion difference factor is

f1 = [ Σ |Rt − Tt| / Σ Rt ] · 100

with values of 0–15 conventionally read as similar (Moore & Flanner, 1996).

Check the conditions first

f2 is only interpretable when the data meet the conditions set out in the FDA (1997) dissolution guidance and the EMA (2010) bioequivalence guideline. In summary:

Exactly how "85 %" is applied (> 85 or ≥ 85) varies; SCIOVANTA asks you to choose the convention explicitly rather than assuming one.

Worked example

Mean cumulative release (%) for a reference and a test tablet:

Time (min)Reference RTest TR − T(R − T)²
51814416
103530525
155246636
206661525
30827939
45939124
Sum34625115

Only the 45-minute point exceeds 85 % for both products, so all six points are retained (n = 6).

  1. Mean squared difference: 115 / 6 = 19.17
  2. 1 + 19.17 = 20.17; its square root is 4.491
  3. 100 / 4.491 = 22.27
  4. log10(22.27) = 1.348; × 50 = f2 = 67.38
  5. f1 = 25 / 346 × 100 = 7.23

Both values fall in the conventional "similar" range. In a real submission you would also report the number of units, the CV at each time point and the conditions above — the calculator lists each of these checks beside the result.

Common mistakes

For variable data, a bootstrap confidence interval for f2 gives a more honest picture. The profile comparison tool provides percentile and BCa intervals from independent-unit resampling.

Worked numbers on this page are reproduced exactly by the SCIOVANTA calculators linked above. Acceptance criteria differ between regulators and products; check the current guidance that applies to your submission.

References

  1. U.S. FDA (1997). Guidance for Industry: Dissolution Testing of Immediate Release Solid Oral Dosage Forms.
  2. European Medicines Agency (2010). Guideline on the Investigation of Bioequivalence (CPMP/EWP/QWP/1401/98 Rev. 1), Appendix I.
  3. Moore JW, Flanner HH (1996). Mathematical comparison of dissolution profiles. Pharmaceutical Technology 20(6):64–74.
  4. Costa P, Sousa Lobo JM (2001). Modeling and comparison of dissolution profiles. European Journal of Pharmaceutical Sciences 13(2):123–133.

Last updated 2026-11-17.