Dissolution · Worked example
Dissolution efficiency (DE) and mean dissolution time (MDT): formulas and a worked example
DE and MDT are model-independent summaries of a whole dissolution profile. DE expresses the area under the curve as a percentage of complete, instant release; MDT is the average time for drug molecules to dissolve. Both are easy to compute by hand — and easy to get subtly wrong.
DE calculator MDT calculator DE & MDT for full datasets
Dissolution efficiency
DE (%) = [ ∫0→t y·dt / (y100 · t) ] · 100
y is the percentage dissolved and y100 = 100 %. The integral is the area under the dissolution curve up to time t, usually computed with the trapezoidal rule; the denominator is the rectangle that complete dissolution at time zero would give (Khan, 1975).
Mean dissolution time
MDT = Σ ( t̂j · ΔMj ) / Σ ΔMj
t̂j is the midpoint of the j-th sampling interval and ΔMj the additional percentage dissolved in that interval (Costa & Sousa Lobo, 2001). A smaller MDT means faster release.
Worked example
Test tablet, cumulative release (%), including the origin:
| Interval (min) | Midpoint t̂ | ΔM (%) | t̂ · ΔM | Trapezoid area (%·min) |
|---|---|---|---|---|
| 0 → 5 (0 → 14 %) | 2.5 | 14 | 35.0 | 35.0 |
| 5 → 10 (14 → 30 %) | 7.5 | 16 | 120.0 | 110.0 |
| 10 → 15 (30 → 46 %) | 12.5 | 16 | 200.0 | 190.0 |
| 15 → 20 (46 → 61 %) | 17.5 | 15 | 262.5 | 267.5 |
| 20 → 30 (61 → 79 %) | 25.0 | 18 | 450.0 | 700.0 |
| 30 → 45 (79 → 91 %) | 37.5 | 12 | 450.0 | 1275.0 |
| Sum | 91 | 1517.5 | 2577.5 |
- DE(45 min) = 2577.5 / (100 × 45) × 100 = 57.28 %
- MDT = 1517.5 / 91 = 16.68 min
Points to report and pitfalls
- State the time window. DE depends on t: DE(45 min) and DE(60 min) are different numbers. Compare products only over the same window.
- MDT covers the observed release only. If release is incomplete (here 91 %), MDT describes the dissolved fraction, not the infinite tail.
- Negative increments (a later sample lower than an earlier one) make MDT undefined; SCIOVANTA withholds MDT rather than silently altering data.
- Include the origin (0, 0) explicitly if your first sample is not at time zero, and say so.
Worked numbers on this page are reproduced exactly by the SCIOVANTA calculators linked above. Acceptance criteria differ between regulators and products; check the current guidance that applies to your submission.
References
- Khan KA (1975). The concept of dissolution efficiency. Journal of Pharmacy and Pharmacology 27(1):48–49.
- Costa P, Sousa Lobo JM (2001). Modeling and comparison of dissolution profiles. European Journal of Pharmaceutical Sciences 13(2):123–133.
Last updated 2026-11-17.