Non-compartmental analysis — worked example

DRAFT - requires author and legal review.

The synthetic observations follow C=10exp(−0.2t) mg/L. Use linear-up/log-down integration. The terminal slope is chosen from contiguous positive post-peak tails with at least three points by best adjusted R². This selection needs scientific review; sparse or multi-phase data can mislead. The app reports extrapolated area and flags values above 20%. It invents no area before the first observation.

051015200246810ConcentrationTime (h)Concentration (mg/L)
Concentration (solid). Synthetic example, not experimental evidence.
Figure data
SeriesTime (h)Concentration (mg/L)
Concentration010
Concentration18.1873075
Concentration26.7032005
Concentration44.4932896
Concentration63.0119421
Concentration82.0189652
Concentration120.90717953
Concentration180.27323722

Reproduce the example

Open the tool, enter the input below or copy it from the downloadable JSON, and select the stated options. These are synthetic measurements.

{
  "tool": "nca",
  "csv": "time,concentration\n0,10\n1,8.18730753077982\n2,6.70320046035639\n4,4.49328964117222\n6,3.01194211912202\n8,2.01896517994655\n12,0.907179532894125\n18,0.273237224472926",
  "timeUnit": "h",
  "concentrationUnit": "mg/L"
}

Computed output

AUCObserved48.63381387763536
AUCFromFirstToInfinity49.99999999999999
extrapolatedPercent2.732372244729261
Cmax10.0
Tmax0.0
lambdaZ0.19999999999999993
halfLife3.465735902799728

Open Non-compartmental analysis Download exact input and output