The synthetic observations follow C=10exp(−0.2t) mg/L. Use linear-up/log-down integration. The terminal slope is chosen from contiguous positive post-peak tails with at least three points by best adjusted R². This selection needs scientific review; sparse or multi-phase data can mislead. The app reports extrapolated area and flags values above 20%. It invents no area before the first observation.
Figure data
| Series | Time (h) | Concentration (mg/L) |
|---|---|---|
| Concentration | 0 | 10 |
| Concentration | 1 | 8.1873075 |
| Concentration | 2 | 6.7032005 |
| Concentration | 4 | 4.4932896 |
| Concentration | 6 | 3.0119421 |
| Concentration | 8 | 2.0189652 |
| Concentration | 12 | 0.90717953 |
| Concentration | 18 | 0.27323722 |
Reproduce the example
Open the tool, enter the input below or copy it from the downloadable JSON, and select the stated options. These are synthetic measurements.
{
"tool": "nca",
"csv": "time,concentration\n0,10\n1,8.18730753077982\n2,6.70320046035639\n4,4.49328964117222\n6,3.01194211912202\n8,2.01896517994655\n12,0.907179532894125\n18,0.273237224472926",
"timeUnit": "h",
"concentrationUnit": "mg/L"
}Computed output
| AUCObserved | 48.63381387763536 |
|---|---|
| AUCFromFirstToInfinity | 49.99999999999999 |
| extrapolatedPercent | 2.732372244729261 |
| Cmax | 10.0 |
| Tmax | 0.0 |
| lambdaZ | 0.19999999999999993 |
| halfLife | 3.465735902799728 |
Open Non-compartmental analysis Download exact input and output
Generated by scripts/build_content.py using the same scientific functions as the application. Independent numerical validation is documented in the source package; no commercial reference program was executed.