SCIOVANTA

Dissolution efficiency and MDT — worked example

DRAFT - requires author and legal review.

Use hours and cumulative release %. Integrate only the measured interval. DE = trapezoidal area divided by [100 × duration], multiplied by 100. MDT = Σ(midpoint time × release increment) / Σ(release increment). The final value is 80%, so observed-interval MDT is not infinite-time MDT. Negative increments cause MDT to be withheld.

01234020406080F1Time (h)Cumulative release (%)
F1 (solid). Synthetic example, not experimental evidence.
Figure data
SeriesTime (h)Cumulative release (%)
F100
F1120
F1240
F1480

Reproduce the example

Open the tool, enter the input below or copy it from the downloadable JSON, and select the stated options. These are synthetic measurements.

{
  "tool": "dissolution",
  "csv": "time,F1\n0,0\n1,20\n2,40\n4,80"
}

Computed output

area160
DEpercent40
MDThours2

Open Dissolution efficiency and MDT Download exact input and output

Generated by scripts/build_content.py using the same scientific functions as the application. Independent numerical validation is documented in the source package; no commercial reference program was executed.